,
APC SMART 600 ups instrukcjaAPC SMART 600 ups instrukcja, APC
[ Pobierz całość w formacie PDF ]
Smart-UPS ® Model 600 h" › _ – ‹‹ m amF m " ›› F ' ƒF dp"= p§ " ›› F ' Test Fzd"4F " ›› F ' User’s Manual Important safety instructions! Please read this manual! Veuillez lire ce manuel! Bitte lesen Sie dieses Anleitungshandbuch! ¡Se ruega leer este manual de instrucciones! This manual provides safety, installation, and operating instructions that will help you get the fullest performance and service life that the UPS has to offer. Please save this manual! It includes important instructions for the safe use of this UPS, and for obtaining factory service if necessary. Future service or storage issues may arise and require reference to this manual. Conserver ces instructions! Cette notice contient des instructions importantes concernant la sécurité. Radio frequency interference Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • reorient the receiving antenna • increase the separation between the equipment and the receiver • connect the equipment into an outlet on a circuit different from that to which the receiver is needed • consult the dealer or an experienced radio/TV technician for help. Shielded communications interface cables must be used with this product. This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la Class B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. Hiermit wird bescheinigt, dass der Smart-UPS 600 Ununterbr e chbar e Str o mversor g ungs-Gerät in Unereinstimmung mit den Bestimmungen der Vfg 1046/1984 funk-entstort ist. Der Deutschen Bundespost wurde das Inverkehrbringen diese Gerates angezeigt und die Berechtigung zur Uberprufung der Serie auf Einhaltung der Bestimmungen eingeraumt. VCCI-1* Table of Contents 1.0 Introduction .................................................................... 3 1.1 Overview .......................................................................................................... 3 1.2 SmartBoost ....................................................................................................... 4 1.3 Battery replacement indicators and test ..................................................... 4 1.4 Remote interfaces ............................................................................................ 4 1.5 Extended capabilities ..................................................................................... 4 2.0 Safety! Sécurité! Sicherheit! ¡Seguridad! ..................... 5 3.0 Presentation .................................................................... 9 3.1 600VA UPS—100 and 120 Vac versions ....................................................... 9 3.2 600VA UPS—220/230/240 Vac version ..................................................... 10 4.0 Installation .................................................................... 11 4.1 Receiving inspection ...................................................................................... 11 4.2 Placement ........................................................................................................ 11 4.3 Connect UPS to service and enable ........................................................... 12 4.4 Plug loads into UPS ...................................................................................... 13 4.5 Check site wiring fault indicator—100, 120 Vac versions only ............. 13 4.6 Switch on load equipment ........................................................................... 14 4.7 Switch on the UPS ........................................................................................ 14 5.0 Operation ...................................................................... 15 5.1 Display features ............................................................................................ 15 5.2 Output Power bar graph ............................................................................. 17 5.3 Line Voltage bar graph ................................................................................. 17 5.4 Audible alarms .............................................................................................. 18 5.5 Option switches ............................................................................................. 19 5.6 Extended capabilities ................................................................................... 21 6.0 UPS Monitoring ............................................................. 25 6.1 Overview ........................................................................................................ 25 6.2 Interface Kits .................................................................................................. 25 6.3 PowerChute Software .................................................................................. 25 6.4 Computer interface port .............................................................................. 26 7.0 Difficulty Difficulté Schwierigkeit Dificultad.............. 27 7.1 Troubleshooting ............................................................................................. 31 7.2 Battery replacement check .......................................................................... 33 7.3 Obtaining service .......................................................................................... 34 1 Table of Contents 8.0 Storing the UPS ............................................................. 35 8.1 Storage conditions ........................................................................................ 35 8.2 Extended storage .......................................................................................... 35 9.0 Specifications ................................................................. 36 9.1 Input ................................................................................................................ 36 9.2 Transfer characteristics ................................................................................ 36 9.3 Output characteristics .................................................................................. 36 9.4 Battery and charger ...................................................................................... 37 9.5 Surge and noise suppression ...................................................................... 37 9.6 Operating Environment ............................................................................... 37 9.7 Physical ........................................................................................................... 38 9.8 Approvals ....................................................................................................... 38 9.9 Typical run times versus load ..................................................................... 39 2 1.0 Introduction 1.1 Overview This equipment is a high-performance, line-interactive, uninterruptible power source (UPS) designed to provide clean, reliable, AC power to computer loads. The UPS’s line-interactive circuit topology (see figure below) offers excellent efficiency, on-line voltage regulation, and fast utility fault response. The UPS’s DC-to-AC inverter is always connected to the output and when operating on-line, part of the inverter circuitry is used “in reverse” to continuously maintain optimum float charge on the battery. The inverter also protects the load from surges and EMI/RFI noise as part of an ad- vanced hybrid surge suppression and filtering network. A unique mode of operation, called SmartBoost, regulates the load voltage by compensating for brownouts or sags without drawing power from the UPS’s battery. The UPS continuously monitors the line for utility failure and prepares the inverter frequency for synchronous transfer of the load. When a utility voltage failure occurs such as a blackout, severe brownout, or an overvoltage condition, the UPS transfers the load to battery power. Transfer to “on-battery” operation typically takes place within 2 milliseconds. The inverter’s output voltage waveshape is a low distortion sine wave. Resynchronization and transfer back to on-line operation is automatic when the line voltage returns to within normal limits. "m ’ OF ⁄ VF % pa ’ F p › F4 › apm §a › 4^ ^" VamV |mp h"d} " ›› F ' h" › pp ’› ⁄ › z⁄ › + a ’ 4^" VamV |zp§F O"ad} mƒF › F — " ›› F ' ^" VF Line interactive UPS block diagram 3 [ Pobierz całość w formacie PDF ] |
Podobne
|